Wadi Muraikh, Jeddah
Office Hours: Sun – Thu, 08:00am - 6:00pm
Access Control Systems in Saudi Arabia

Zero-Trust Physical Security Architectures

Access Control Systems in Saudi Arabia

Access Control Systems – MHA Solutions Saudi Arabia (1)
Access Control Systems – MHA Solutions Saudi Arabia (2)
Access Control Systems – MHA Solutions Saudi Arabia (3)
Access Control Systems – MHA Solutions Saudi Arabia (4)

Access Control Fails in Predictable Ways

MHA Solutions designs, installs and maintains access control systems for industrial plants, government facilities, healthcare, commercial buildings and multi-site estates across Saudi Arabia. Biometric, card and mobile credentials, turnstiles and gates, integrated with attendance, HR provisioning and CCTV — and designed so that a locked door never becomes a blocked escape route. Access control systems rarely fail because the technology stopped working. They fail because of how they are run, and the failures are remarkably consistent from site to site. The most common is credentials that were never revoked. Someone leaves, their card is not collected or not deactivated, and it continues to open doors for months. On a site with contractors and turnover, the number of live credentials belonging to people who no longer work there can be substantial — and nobody knows, because nobody audits it. The second is doors that get propped open. A turnstile lane that cannot handle the shift-change flow, or a reader that fails to read dusty fingers on an industrial site, produces a queue. Queues produce workarounds, and the workaround is always the same: someone wedges the door. The system is now decorative. The third is credentials that can be copied. A great deal of the access control installed in this region runs on card technology that can be duplicated with equipment costing very little, which means the audit trail showing who entered is not evidence of anything. And the fourth is the serious one: systems that impede escape. An access-controlled door on an escape route that does not release correctly on a fire alarm is a safety failure and a compliance failure, and it is more common than it should be. We design around all four. Provisioning integrated with HR or directory systems so leavers lose access automatically. Readers and throughput specified for the conditions and the actual peak flow. Credential technology chosen for what it is protecting. And egress arrangements designed and tested with the fire strategy, not bolted on afterwards.

Our Access Control Services

01

Site Survey and System Design

Door and gate schedule, security zoning, credential technology selection, reader specification against the environment, throughput calculation at genuine peak flow, egress design agreed with the fire strategy, and network and controller architecture. The output is a specification and drawing set you can tender against.

02

Supply and Installation

Readers, controllers, locking hardware, turnstiles, gates and barriers, with our own cabling and containment, power supplies and battery backup, and structured cabling where the installation needs it. We carry out the electrical works ourselves rather than subcontracting them.

03

Commissioning and Configuration

Access levels, time zones and holiday schedules, anti-passback and interlocking where required, user enrolment, operator permissions, and full testing of every door — including the fire alarm release interface on every escape route door, tested and documented rather than assumed.

04

Integration

HR and directory integration for automatic provisioning and revocation, attendance and payroll, CCTV, visitor management, lift control, intrusion and fire systems. We can integrate with platforms you already have rather than requiring a full replacement.

05

Maintenance and Support

Scheduled maintenance covering reader condition and cleaning, lock and door hardware, turnstile and barrier mechanisms, battery backup, controller and software health, firmware updates, and testing of emergency release and fire interfaces. Fault response and repair on call.

06

Security Assessment of Existing Systems

Assessment of an installed system covering credential technology and whether it is one of the compromised formats, active credential audit, egress compliance review, coverage against current requirements, and system health. We take on systems installed by others.

07

Credential Migration

Upgrading an estate from legacy proximity or early smart card credentials to secure modern credentials, using multi-technology readers so the transition happens at a manageable pace rather than as a single cutover.

Explore Security Subsystems

Need Help with Engineering Solutions?

Talk to MHA Solutions for expert advice on Power, IT, and Security systems that fit your space. We cover Riyadh, Jeddah, Dammam, and other cities with custom plans.

Solutions Tailored to Your Infrastructure

Physical Access Hardware

Door Locking Hardware

Door Locking Hardware

Electromagnetic locks, electric strikes and electric mortice locks, selected against the door type, the security requirement and — critically — the escape route status of the opening. Each installation includes the associated door position monitoring, request-to-exit device and emergency release where required.

Key Applications:

  • Electromagnetic locks
  • Electric strikes
  • Electric mortice locks

Available Specifications:

Door monitoring, request-to-exit and emergency release

Request a Quote
Speed Gates and Optical Turnstiles

Speed Gates and Optical Turnstiles

The right choice for corporate lobbies, headquarters buildings and high-traffic entrances where throughput and appearance both matter. Optical detection distinguishes a single authorised passage from tailgating, and the units fail open on alarm. Lane count should be sized against genuine peak flow rather than average. In Saudi buildings the peaks are sharp and predictable — shift changes, prayer times, the start and end of the working day — and a lobby that backs up at those moments produces exactly the propped-door behaviour the system was installed to prevent.

Key Applications:

  • Corporate lobbies
  • Headquarters buildings
  • High-traffic entrances

Available Specifications:

Optical tailgating detection · fail open on alarm

Request a Quote
Tripod and Full-Height Turnstiles

Tripod and Full-Height Turnstiles

Tripod turnstiles for controlled entry in industrial and commercial settings, and full-height turnstiles where physical security genuinely matters — site perimeters, plant entrances, contractor gates and stadium or venue access. Full-height units cannot be climbed or crawled under, and they require a separate designated escape route because they are not one.

Key Applications:

  • Site perimeters
  • Plant entrances
  • Contractor gates
  • Stadium or venue access

Available Specifications:

Full-height units need a separate escape route

Request a Quote
Vehicle Access

Vehicle Access

Barriers, sliding and swing gates, road blockers and bollards, with loop detection, safety sensors and number plate recognition where vehicle identification is required. Vehicle access is usually where an industrial site's security is weakest, because gates are frequently left open for convenience during busy periods.

Key Applications:

  • Barriers and gates
  • Road blockers and bollards
  • Number plate recognition

Available Specifications:

Loop detection and safety sensors

Request a Quote
Interlocks and Controlled Vestibules

Interlocks and Controlled Vestibules

Two-door arrangements where only one door may open at a time, used for high-security areas, cash handling, data centres and clean or controlled environments. These need careful egress design, since the interlock is by definition a restriction on movement.

Key Applications:

  • High-security areas
  • Cash handling
  • Data centres
  • Clean or controlled environments

Available Specifications:

Only one door open at a time

Request a Quote
Controllers and System Hardware

Controllers and System Hardware

Door controller panels supporting varying door counts, IP or serial connected, with local decision-making so that doors continue to function correctly if the network or server is unavailable — which matters more than it sounds, because networks fail and doors still need to work sensibly when they do.

Key Applications:

  • IP or serial connected
  • Varying door counts

Available Specifications:

Local decision-making if the network is unavailable

Request a Quote

Ideal For

Access Control by Sector

01

Industrial & Manufacturing

Plant entrances, contractor gates, restricted process areas and stores, with reader technology specified for dust and manual work, and vehicle access at goods gates.

Key Benefits:

  • Plant entrances and contractor gates
  • Readers specified for dust and manual work
  • Vehicle access at goods gates
02

Government & Infrastructure

Controlled facilities where credential security, audit integrity and system assurance carry as much weight as the physical hardware.

Key Benefits:

  • Credential security
  • Audit integrity
  • System assurance
03

Healthcare

Wards, theatres, pharmacy and controlled drug stores, with strict egress compliance and contactless credentials where hygiene matters.

Key Benefits:

  • Wards, theatres and pharmacy
  • Strict egress compliance
  • Contactless credentials
04

Corporate & Multi-Tenant Buildings

Lobby speed gates, lift destination control, floor and tenant separation, and visitor management.

Key Benefits:

  • Lobby speed gates
  • Lift destination control
  • Visitor management
05

Oil, Gas & Petrochemical

Site and plant access with high contractor turnover, where automated provisioning and expiry matter more than anywhere else.

Key Benefits:

  • High contractor turnover
  • Automated provisioning and expiry
06

Data Centres

Layered access from building to hall to cabinet, interlocked vestibules, multi-factor at critical points, and a defensible audit trail.

Key Benefits:

  • Layered access from building to cabinet
  • Interlocked vestibules
  • Multi-factor at critical points
07

Education

Campus buildings, laboratories and restricted areas, with high user counts and frequent population changes.

Key Benefits:

  • Campus buildings and laboratories
  • High user counts
08

Logistics & Warehousing

Gate control, yard access, vehicle recognition and separation of operational from administrative areas.

Key Benefits:

  • Gate control and yard access
  • Vehicle recognition

Can Your Access Cards Be Copied? Probably.

A large proportion of the access control installed across this region relies on credential technology that can be duplicated cheaply, and most of the organisations relying on it do not know that.

Low-frequency proximity cards, the 125 kHz technology that has been standard for decades, transmit a fixed identification number with no encryption and no authentication. The reader asks; the card answers; anyone listening hears the same number. Cloning devices capable of reading and writing these credentials are widely available and inexpensive. A card can be copied in seconds, from a pocket, without the holder knowing.

The situation with early smart cards is not much better. The first widely deployed 13.56 MHz smart card format used a proprietary cipher that was broken publicly many years ago, and tools to exploit it have been in circulation ever since. It is still installed in an enormous number of buildings, and it is still being sold, because it works and it is cheap.

This matters for two reasons. Obviously, someone can gain entry using a copied card. Less obviously, and often more importantly, it undermines the audit trail. If a credential can be duplicated, then a record showing that card 4471 opened the server room at 02:40 is not evidence that the holder of card 4471 was there. For any organisation that relies on access records for investigations, compliance, or disciplinary matters, that is a significant weakness.

The modern answer is credentials using mutual authentication and current encryption — where the reader and the card verify each other cryptographically and the exchange cannot simply be replayed. Contemporary secure smart card families and properly implemented mobile credentials both do this. They cost more per credential and considerably less than the consequences of a copied one.

How do you find out what you have? The card itself usually gives it away — the technology, and often the format, can be identified from markings, from the reader model, or from the system configuration. We can assess an existing installation and tell you plainly what credential technology it uses and whether it is one of the compromised formats.

The good news is that upgrading rarely means replacing everything. Multi-technology readers can accept both old and new credentials during a transition, so the estate can be migrated at a sensible pace rather than in a single disruptive cutover — issue new credentials as people are re-badged, and switch off the legacy format once the population has moved across.

Where the doors are protecting something that genuinely matters — server rooms, cash handling, controlled substances, plant areas, records — the credential technology should reflect that, and a single factor should probably not be the whole control.

Biometric Access — Which Technology Works Where

Biometrics remove the two weakest points of a card system: credentials that can be shared, and credentials that can be copied. They introduce their own considerations, and the choice of technology matters far more than most specifications acknowledge — particularly in industrial environments where the standard option frequently fails.

Every biometric system balances two error rates against each other. A false accept lets in the wrong person. A false reject turns away the right one. Tuning the system to reduce one increases the other, and there is no setting that eliminates both. A system tuned too tightly produces queues and workarounds; tuned too loosely, it stops being a control. Where the security requirement is high, the correct answer is usually a second factor rather than an impossibly tight biometric threshold.

01

Fingerprint Readers

The most common and the most frequently mis-specified. Standard optical readers work well in clean office environments and struggle badly with dry skin, worn fingerprints, dust, moisture and manual labour — which describes most industrial and construction workforces.

Multispectral readers read below the surface of the skin rather than only the surface pattern, so they continue to work with dirty, wet, dry or worn fingers where an optical reader would fail repeatedly. On an industrial site the difference is the difference between a system people use and a system people bypass. If a fingerprint system is being specified for a plant, a warehouse or a construction site, this is the single most important decision on the page.

02

Facial Recognition

Contactless, fast, and well suited to high-throughput entrances and to environments where hands are gloved or dirty. Performance depends heavily on lighting, so units with infrared or depth sensing perform far more consistently than camera-only devices, particularly at entrances with strong daylight behind the subject.

Also the practical choice where hygiene matters, and popular in healthcare and food handling for that reason.

03

Palm Vein and Iris

Contactless, difficult to spoof, and unaffected by the surface condition of the skin. Higher cost per reader, so normally deployed at a small number of high-security points rather than across an estate.

04

Liveness Detection and Multi-Factor

Any biometric worth deploying should include anti-spoofing capability, so a photograph or a lifted print is rejected. For genuinely sensitive areas, biometric combined with a card or PIN is stronger than any single factor, and it is the standard approach for server rooms, cash areas and controlled stores.

05

Biometric Data and Privacy

Biometric data is personal data, and its collection, storage and processing carry obligations under Saudi data protection law. Systems that store mathematical templates rather than images, and that keep those templates on the device or on a properly secured server, are easier to defend from a compliance perspective. This should be established with your legal or compliance function before deployment, not after.

A Locked Door Must Never Become a Blocked Escape Route

Access control restricts movement. Fire safety requires that people can always get out. Reconciling those two is the most important part of an access control design, and it is the part most often treated as an afterthought.

The central concept is how a lock behaves when power is removed. Fail-safe locking releases on loss of power, so the door can be opened. Fail-secure locking stays locked. Both are correct in the right place, and using the wrong one is a serious error in either direction — a fail-secure lock on an escape route can trap people, and a fail-safe lock on a high-security store means a power interruption opens it.

Doors on escape routes must release on activation of the fire alarm, and that interface has to be a properly engineered hard-wired connection rather than a software instruction that depends on a server, a network and an application all being functional at the moment of a fire.

Free egress from the secure side is a related principle. In most cases a person inside should be able to leave without presenting a credential, using a request-to-exit device or mechanical door hardware. Where an installation controls exit as well as entry — for anti-passback, or to prevent theft — the egress arrangement needs particular care and explicit agreement with the fire strategy.

Emergency release units, commonly break-glass or emergency-break devices, provide a manual override at controlled doors on escape routes. Their position and quantity are part of the design rather than an installation detail.

Turnstiles and speed gates need the same treatment. Optical gates should fail open on alarm or power loss, and full-height turnstiles need a designated escape route around them, because a full-height turnstile is not an escape route under any circumstances.

In Saudi Arabia these arrangements fall under Civil Defence requirements as part of the building's fire and life-safety approval. The access control design has to be consistent with the approved fire strategy, and the interfaces have to be tested and documented at commissioning — not simply installed and assumed.

We design egress with the fire strategy from the start, test every interface at commissioning, and record the results in the handover documentation. If an existing installation concerns you, we will assess it and tell you plainly what we find.

Joiners, Leavers and the Credentials Nobody Revoked

The most common real-world access control failure has nothing to do with the technology. It is that credentials outlive the people they were issued to.

Somebody leaves. Their card is not collected, or it is collected but never deactivated, or they were a contractor and nobody was responsible for them in the first place. The credential stays live. On a site with meaningful turnover, the number of active credentials belonging to people who no longer work there can be significant — and it is invisible, because nobody runs the report.

The fix is to stop treating access provisioning as a manual security task. Where the access control system is integrated with HR records or a directory service, joiners are provisioned from the authoritative record and leavers are revoked automatically when they are removed from it. The security team is no longer relying on being told.

Other integrations that earn their cost:

01

Time and attendance

The same credential presentation that opens the door also records attendance, feeding payroll without separate clocking. This is covered on our attendance systems page.

02

CCTV

An access event links directly to the corresponding CCTV footage and an investigation becomes a matter of seconds rather than an afternoon of scrubbing recorded video.

03

Visitor management

Issuing temporary credentials with defined validity and area permissions, so a contractor badge expires by itself rather than relying on somebody remembering.

04

Lift destination control

Restricting which floors a credential can reach, which is often the practical way to secure a multi-tenant building.

05

Intrusion detection and fire systems

So the security systems behave coherently rather than as separate installations that happen to share a building.

We also recommend a periodic credential audit regardless of integration — a report of all active credentials, when each was last used, and which have not been used in months. It is a straightforward exercise and it routinely surprises people.

Specifying Access Control for Saudi Conditions

Readers and gates installed outdoors or at industrial entrances here face conditions that determine whether the system gets used or bypassed.

01

Heat on outdoor readers

Every reader has a stated operating temperature range, and a unit mounted in direct sun on a gate post or a turnstile in an open compound will exceed the ambient air temperature substantially. Shaded mounting positions, weather hoods and outdoor-rated units are not refinements here. Touchscreen and display-equipped readers are particularly affected.

02

Dust on fingerprint readers

This is the most frequent cause of an access control system falling into disuse on an industrial site. Standard optical fingerprint sensors accumulate dust on the platen and struggle with dirty or worn fingers, so read failure rates climb, queues form, and within a few months the door is propped open at shift change. Multispectral sensors handle these conditions far better and are worth the difference on any site where the workforce works with their hands.

03

Sand in mechanisms

Turnstile and barrier mechanisms in exposed locations need appropriate ingress protection and a maintenance interval that reflects the environment rather than a manufacturer default written for a temperate climate.

04

Coastal corrosion

Along the Red Sea coast, salt-laden air attacks reader housings, gate mechanisms, fixings and cable glands. Stainless or properly coated hardware costs more initially and considerably less over a few years.

05

Peak flow patterns

Throughput sizing needs to reflect how the building is actually used. Shift changes, prayer times and the start and end of the working day create sharp, predictable peaks, and a lane count sized on average flow will queue at exactly the moments that matter most.

Brands We Supply

We supply ZKTeco and HID systems alongside other manufacturers, selected against the application. A corporate lobby, an industrial gate and a hospital controlled-drug store are three different specifications, and defaulting to one brand for all of them produces a compromise in at least two of the three.

Where a client already has an installed platform they intend to keep, we work with it rather than proposing replacement for its own sake.

Access Control Installation and Service Across Saudi Arabia

We survey, design, install and maintain access control systems Kingdom-wide from our base in Jeddah — Riyadh, Dammam, Khobar, Jubail, Yanbu, Makkah, Madinah, Taif, Abha and remote industrial sites. Surveys, installation, commissioning and maintenance are carried out by our own engineers.

Access Control — Frequently Asked Questions

Can our access cards be copied?+

Quite possibly. Low-frequency proximity cards transmit a fixed number with no encryption and can be duplicated in seconds with inexpensive equipment. The first widely deployed smart card format used a cipher that was broken publicly years ago and remains in enormous numbers of buildings. Both are still being sold. Modern secure credentials use mutual authentication and current encryption, which prevents simple copying. We can assess your existing installation and tell you which technology you are actually running.

Does it matter if a card can be copied?+

It matters in two ways. Someone can gain entry using a duplicate, which is the obvious problem. The less obvious and often more serious one is that your audit trail stops being evidence — a record showing a particular card opened a door no longer proves who was there. For any organisation using access records in investigations, compliance or disciplinary matters, that is a real weakness.

Do fingerprint readers work in dusty industrial environments?+

Standard optical readers struggle badly with dust, moisture, and dry or worn fingerprints, which describes most industrial and construction workforces. Read failures build queues, queues produce workarounds, and the system falls into disuse. Multispectral sensors read below the surface of the skin rather than only the surface pattern and continue working in those conditions. If you are specifying fingerprint readers for a plant, warehouse or construction site, this is the most important decision you will make on the project.

What happens to controlled doors during a fire?+

Doors on escape routes must release on fire alarm activation, and that interface should be a hard-wired connection rather than a software instruction depending on a server and a network being functional during a fire. Escape route doors normally use fail-safe locking so they release on loss of power, and emergency release units provide manual override. Optical gates should fail open, and full-height turnstiles require a separate designated escape route because they are not one. These arrangements fall under Civil Defence requirements as part of the building's fire approval, and they should be tested and documented at commissioning.

Can access control integrate with our HR system or payroll?+

Yes, and it is one of the more valuable integrations available. Provisioning from HR records or a directory service means joiners are enrolled from the authoritative record and leavers are revoked automatically when removed from it, rather than relying on somebody remembering to deactivate a card. The same credential presentation can also feed time and attendance directly into payroll, removing separate clocking.

How do we know if old employees still have access?+

Run a credential audit — a report of all active credentials, who they belong to, and when each was last used. It is a straightforward exercise and it routinely finds live credentials belonging to people who left months earlier, particularly on sites with contractors. We can carry this out as part of an assessment of an existing system, and integration with HR records prevents it recurring.

How many turnstile lanes do we need?+

Size against genuine peak flow rather than average. In Saudi buildings the peaks are sharp and predictable — shift changes, prayer times, and the start and end of the working day. A lobby sized on average flow will queue precisely at the moments that matter, and queues produce propped doors and tailgating, which defeats the system. We calculate throughput against the actual population and peak pattern.

Which access control brands do you supply?+

We supply ZKTeco and HID alongside other manufacturers, selected against the application rather than defaulting to a single brand for every situation. Where you already have an installed platform you intend to keep, we work with it rather than proposing replacement for its own sake.

Is biometric data subject to privacy regulation in Saudi Arabia?+

Biometric data is personal data and its collection, storage and processing carry obligations under Saudi data protection law. Systems that store mathematical templates rather than images, and that hold those templates on the device or on a properly secured server, are generally easier to defend from a compliance standpoint. This should be established with your legal or compliance function before deployment rather than after, and we will design the system around whatever position they take.

Can you take over an access control system installed by someone else?+

Yes. We assess, maintain, extend and upgrade existing systems regardless of who installed them. An assessment covers the credential technology in use and whether it is one of the compromised formats, an audit of active credentials, egress compliance, coverage against current requirements, and system health. Where an upgrade is warranted, multi-technology readers allow the credential estate to be migrated gradually rather than in a single disruptive cutover.

Start With an Assessment

If you have an existing system, we will assess what credential technology it uses, audit which credentials are still active, and review egress compliance — and tell you plainly what we find. If you are starting from nothing, tell us about the site and the doors and we will survey it and produce a specification.

Our Story

One Engineering Partner for Power, IT, Security and Electrical Works

Most facilities in the Kingdom deal with separate suppliers for power, IT and security, then discover the gaps between them at the worst possible moment. The UPS vendor points at the electrical contractor. The IT supplier says the rack was never their scope. Nobody owns the problem.

MHA Solutions covers all four disciplines with one engineering team. That means one point of accountability for the UPS, the distribution board feeding it, the server rack it protects and the access control system on the door of the room.

We work with industrial plants, healthcare facilities, government entities, data centres, telecom operators and major infrastructure contractors across Saudi Arabia. Our engineers handle the full lifecycle: site survey and load study, system design and specification, supply, installation, testing and commissioning, and ongoing maintenance under contract.

Equipment that performs well in a temperate climate does not always survive a Saudi plant room. Ambient temperatures above 45°C shorten battery life, airborne dust clogs filters and cooling paths, and salt-laden humidity on the Red Sea coast attacks enclosures and terminations. We specify for those conditions from the start, because replacing equipment early is far more expensive than sizing it correctly on day one.

Discover Our Journey

100+

Happy customers

50+

Brand partnerships

20+

Years in business

4

Countries Served

Welcome to MHA Solutions
20+
Years of Excellence

OUR SERVICES

Built for power, security and IT infrastructure

Explore engineered solutions for mission-critical environments across power, IT and security.

All

Engineering reliable infrastructure for critical facilities.

Power

Engineering reliable infrastructure for critical facilities.

Security

Engineering reliable infrastructure for critical facilities.

IT

Engineering reliable infrastructure for critical facilities.

UPS Systems

Power Systems

UPS Systems

Reliable continuous power protection for mission critical operations.

Explore
Diesel Generators

Power Systems

Diesel Generators

Dependable backup power engineered for industrial and commercial use.

Explore
Voltage Stabilizers (AVR)

Power Systems

Voltage Stabilizers (AVR)

Precision automatic voltage stabilization for sensitive equipment.

Explore
Transformers

Power Systems

Transformers

Efficient power distribution and voltage conversion for industrial facilities.

Explore
Electrical Contracting

Power Systems

Electrical Contracting

Professional electrical contracting and installation services for critical infrastructure.

Explore
Load Bank Rental & Testing

Power Systems

Load Bank Rental & Testing

Resistive and reactive load bank hire for generator, UPS and data centre commissioning.

Explore
UPS Batteries & DC Systems

Power Systems

UPS Batteries & DC Systems

VRLA, lithium and industrial DC battery systems engineered for Saudi heat conditions.

Explore
UPS Rental

Power Systems

UPS Rental

Short and long-term UPS rental for shutdowns, data centre maintenance, events and construction.

Explore
Generator Rental

Power Systems

Generator Rental

Diesel generator rental for construction, events, shutdowns and emergency backup.

Explore
CCTV Systems

Security

CCTV Systems

High-definition video surveillance & AI analytics for critical infrastructures.

Explore
Access Control Systems

Security

Access Control Systems

Intelligent biometric and RFID entry identity management systems.

Explore
Cyber Security Services

Security

Cyber Security Services

Next-generation firewalls and advanced endpoint protection platforms.

Explore
Biometric Attendance Systems

Security

Biometric Attendance Systems

Fingerprint and face recognition time-attendance systems with payroll integration.

Explore
Enterprise Servers

IT Infrastructure

Enterprise Servers

High-performance computing and data management architectures.

Explore
Server Racks & PDUs

IT Infrastructure

Server Racks & PDUs

Structurally superior, thermally optimized rack containment systems.

Explore
Network Switches & Solutions

IT Infrastructure

Network Switches & Solutions

High-speed, zero-latency core and edge switching fabrics.

Explore
Workstations & Business Laptops

IT Infrastructure

Workstations & Business Laptops

High-performance computing power for CAD, engineering and data-intensive workloads.

Explore
Structured Cabling & Fiber Optic

IT Infrastructure

Structured Cabling & Fiber Optic

End-to-end structured cabling, data center build and IT lifecycle management.

Explore
Data Centre Solutions

IT Infrastructure

Data Centre Solutions

Turnkey data centre build, hot and cold aisle containment and legacy migration.

Explore
IT AMC & Support Contracts

IT Infrastructure

IT AMC & Support Contracts

Annual maintenance contracts for servers, networks and IT infrastructure with 24/7 SLA response.

Explore

Contact Us

Let's Build A Resilient Future Together

Get a Free Quote Today