.png)
SEAMLESS CONNECTIVITY
MHA Solutions designs, supplies, installs and supports network infrastructure for offices, campuses, industrial sites and multi-site organisations across Saudi Arabia — managed and PoE switching, enterprise wireless designed from an actual site survey, and WAN connectivity between sites. We work with Cisco and other enterprise platforms, and we install the cabling and the power behind the equipment as well. Network problems rarely present as network problems. They present as an application being slow, a video call breaking up, cameras dropping offline, a warehouse scanner losing connection at one end of the aisle, or a site that "has Wi-Fi" but nobody can hold a call in the meeting room. By the time anyone investigates, the usual causes are the same handful. A switch whose power budget was exceeded when the last batch of cameras went in, so devices reboot under load. Access points added one at a time wherever there was a power socket, all running at full transmit power, interfering with each other. A network that grew flat, so everything can reach everything and a single compromised device has the run of the building. Or uplinks that were adequate three years ago and are now the bottleneck for every user behind them. None of these are equipment faults. They are design faults, and they accumulate because networks get extended rather than designed — a switch here, an access point there, each addition sensible on its own. We approach it the other way round. Wireless is designed from a site survey rather than an assumption about coverage. Switching is specified with the power budget calculated against everything that will draw from it, including growth. The network is segmented so a problem in one part does not become a problem everywhere. And it is documented and labelled, so whoever works on it next can understand it. We work on everything from a single office to campus and multi-site estates, and we take on networks we did not build.
Requirements assessment, topology design, switching and uplink sizing, IP addressing and VLAN structure, resilience and segmentation design, and a documented design you can build or tender against. Design is the part most often skipped, and it is the part that determines everything afterwards.
Predictive modelling from building plans, on-site validation measuring what the building actually does to signal, and a design covering access point placement, count, channel plan and power settings — sized for coverage or capacity according to which problem each area actually has. We also survey existing deployments that are underperforming and produce a remediation plan.
Switches, access points, routers, transceivers and the rack infrastructure around them, installed with our own cabling and containment. We carry out the structured cabling and the electrical work rather than subcontracting the physical layer.
VLAN and routing configuration, quality of service for voice and video, PoE budgeting and port configuration, wireless controller setup, guest access separation, resilience and failover testing, and management platform configuration. Everything documented and labelled.
Assessment of an existing network — topology and how it actually grew, PoE budget headroom, uplink and bottleneck analysis, wireless coverage and interference, segmentation, equipment age and support status, and documentation quality. This is the usual starting point for an inherited network nobody fully understands.
Site-to-site connectivity design, SD-WAN deployment, remote site links and centralised management across a distributed estate.
Monitoring, fault response, configuration management, firmware and security updates, and lifecycle planning. Network equipment reaches end of support like any other hardware, and running unsupported switches is a security exposure as well as an operational risk.
Talk to MHA Solutions for expert advice on Power, IT, and Security systems that fit your space. We cover Riyadh, Jeddah, Dammam, and other cities with custom plans.
.png)
Managed switches give you VLANs for segmenting traffic, quality of service for prioritising voice and video, link aggregation for resilient uplinks, monitoring, and access control at the port. On any network beyond a handful of devices, the manageability is the reason to buy rather than a feature list. Layer 3 switches add routing, which lets traffic move between VLANs at the switch rather than travelling to a router and back. On a campus or a large site that removes a bottleneck and simplifies the design considerably. Unmanaged switches remain reasonable for very small, static installations — but adding one into a managed network is how blind spots appear, since it carries traffic nobody can see or control.
Layer 2 and Layer 3
.png)
Power over Ethernet carries power and data on one cable, which is what makes cameras, access points, IP phones, door controllers and sensors practical to deploy — no separate power at each device position. The critical specification point is the switch power budget, and it is the most common mistake in this category. A switch with 24 PoE ports rarely supplies full power to all 24 simultaneously; the total available wattage is a separate figure from the port count. Add high-draw devices — PTZ cameras, cameras with heaters, high-power access points — and the budget is consumed far faster than the port count suggests. When it runs out, devices stop powering up or reboot intermittently under load, which presents as a device fault rather than a switch limitation. We calculate the power budget against the actual devices plus headroom for what gets added later, because something always does.
Power budget calculated against the actual devices
.png)
Higher-speed switching for server connectivity, aggregation and building backbones, with fiber uplinks where distance or capacity requires them. Copper Ethernet is limited to around a hundred metres, so any run beyond that — between buildings, across a campus, along an industrial site — needs fiber, and that has to be designed in rather than discovered during installation.
Fiber uplinks where distance or capacity requires them
.png)
Hardened, fanless switches on DIN rail mounts for control panels, plant floors and outdoor cabinets, specified for wide operating temperature ranges and dust. Ring topologies provide redundant paths so a single cable break does not stop the process. These belong to the operational network rather than the corporate one, and how the two connect is a security decision as much as a networking one.
Hardened, fanless, DIN rail mounted
.png)
Stacking allows multiple switches to be managed as a single unit with a shared configuration and resilient interconnection, which simplifies management and removes single points of failure at the access layer. Combined with redundant uplinks and link aggregation, it means a switch or a cable can fail without taking a floor offline.
Managed as a single unit
Hardened switching for plant floors and control panels, ring topologies for redundant paths, and a properly designed boundary between the operational and corporate networks.
Campus and office switching, enterprise Wi-Fi designed from survey, and WAN connectivity with central management across distributed sites.
Clinical network reliability, wireless coverage across large multi-building sites with seamless roaming, medical device connectivity and segmentation between clinical and administrative traffic.
Campus-wide wireless designed for density in lecture spaces rather than coverage alone, backbone capacity, and separated guest and staff access.
Wireless coverage for scanners and mobile devices in high-racking environments, where metal racking and aisle geometry make survey work essential rather than optional.
Guest wireless with capacity for high device counts per room, separated from operational systems, and coverage across large properties.
Segmented networks with documented configuration, access control at the port, and equipment lifecycle management for compliance.
Most business Wi-Fi is installed rather than designed. Access points go where there is a convenient ceiling tile and a power source, transmit power is left at maximum on the assumption that stronger is better, and the result is a network that covers the building and performs badly.
The counterintuitive part is that more access points at full power make things worse rather than better. Wi-Fi has a limited number of non-overlapping channels. When neighbouring access points broadcast loudly on the same channel, they interfere with each other and devices spend time waiting rather than transmitting. Turning power down and placing units deliberately usually improves performance more than adding hardware does.
The second thing that gets missed is that coverage and capacity are different problems. A warehouse needs signal across a large area with few simultaneous users — that is a coverage problem. A lecture theatre or a meeting room needs to handle many devices in a small space — that is a capacity problem, and it needs more access points at lower power rather than fewer at high power. Designing for one when you have the other produces a network that measures fine on a signal-strength map and fails in practice.
This is why we start with a survey. A predictive design models coverage from the building plans and construction materials, and an on-site validation survey measures what the building actually does to the signal — because plans and reality diverge, particularly in the heavy concrete and block construction common here, which attenuates signal considerably more than a lightweight partitioned office. Metal racking in warehouses, foil-backed insulation and glass partitioning all change the answer too.
From the survey comes the design: access point placement and count, channel plan, transmit power settings, and the switching and cabling needed to support it. Every access point needs a cable run within the copper distance limit and PoE budget on the switch feeding it, so the wireless design and the wired design are the same project.
Beyond the physical design, an enterprise deployment needs a controller or cloud management platform so the network behaves as one system rather than as a set of independent units — consistent configuration, seamless roaming as people move between access points, guest access separated from the corporate network, and visibility of what is actually happening when someone reports a problem.
Outdoor coverage — yards, compounds, car parks, plant areas — needs weather-rated access points with appropriate mounting and, here, attention to heat and sun exposure at the mounting position.
Organisations with more than one location have to connect them, and the options have changed considerably in recent years.
Traditional multi-site connectivity used dedicated circuits from a single provider, backhauling all traffic — including internet and cloud traffic — through a central site. That is predictable and expensive, and it makes little sense when most of what people use now sits in the cloud rather than in your data centre.
Software-defined WAN takes a different approach. Multiple connections at each site — different providers, different technologies — are managed as one, with traffic steered according to policy and current conditions. Cloud traffic can go directly to the internet rather than crossing the network first, and if one link degrades, traffic moves to another without anyone intervening. Policy is applied centrally rather than configured device by device, which matters when there are twenty sites rather than two.
The practical advantages for a distributed organisation here are resilience through diverse links rather than a single circuit, better performance for cloud applications, and central management of what would otherwise be a large number of independently configured routers.
Whether it is worth it depends on how many sites you have, how much you rely on cloud services, and what your current arrangement costs. For a two-site organisation with a working connection, the answer is often no. For a distributed operation with sites across the Kingdom, it usually pays for itself.
We design and deploy site connectivity, remote site links, and the routing and resilience arrangements behind them.
Networks tend to grow flat. Everything gets connected, everything can reach everything, and it works — until something goes wrong, at which point there is nothing limiting how far the problem spreads.
The clearest example is devices that should never have needed access to anything much: cameras, door controllers, printers, building management systems, industrial controllers. Each is a network-connected computer, many run software that is rarely updated, and on a flat network any one of them is a route to everything else. Cameras in particular have been used as an entry point into corporate networks often enough that it is a standard finding in security assessments.
Segmentation separates the network into zones and controls what can pass between them. Cameras and building systems sit on their own segments with access only to what they genuinely need. Guest wireless is separated from corporate. Operational technology is separated from IT with a controlled boundary. And a problem in one zone stays in that zone.
The other benefit is performance and diagnosis: broadcast traffic stays local, and when something misbehaves it is far easier to locate.
Segmentation is designed into the switching and wireless configuration rather than added afterwards, which is why it belongs in this conversation rather than as a separate security project. Where the requirement extends to firewalls, monitoring and policy enforcement, our cyber security team handles that.
Wi-Fi performance depends heavily on what the signal has to pass through, and the reinforced concrete and block construction common in Saudi buildings attenuates signal far more than the lightweight partitioning many predictive design tools assume by default. A design based on generic wall types will consistently overestimate coverage. This is the single strongest argument for an on-site validation survey rather than a purely predictive design.
Switches generate heat and sit in rooms that are frequently small, unventilated and treated as storage. A comms room at 40°C shortens equipment life and causes intermittent faults that get blamed on the network rather than the room. Comms room cooling belongs in the design.
Access points, industrial switches and enclosures mounted outdoors face direct sun that takes the housing well above ambient air temperature. Mounting position, shading and enclosure specification all matter, and a unit rated for a temperature range will still fail if it sits in full sun on a south-facing wall.
Industrial sites, campuses and compounds routinely exceed the hundred-metre copper limit between buildings. Fiber backbone needs designing in from the start — retrofitting it after the copper runs have failed to reach is expensive and disruptive.
Fanless industrial switches exist for a reason. In plant and workshop environments, equipment with cooling fans draws dust through itself continuously, and either the enclosure keeps it out or the equipment life is shortened.
We supply Cisco alongside other enterprise networking platforms, selected against the requirement, the management model you want and the support available locally.
Platform choice matters more than it appears, because it is a long commitment. Switches and access points typically stay in service for years, the management platform shapes how your team works day to day, and mixing platforms across an estate multiplies the operational effort. We would rather discuss which platform suits how you actually operate than lead with a brand.
We design, install and support networks Kingdom-wide from our base in Jeddah — Riyadh, Dammam, Khobar, Jubail, Yanbu, Makkah, Madinah, Taif and remote industrial sites. Surveys, installation, commissioning and support are carried out by our own engineers.
No, and this is the most common mistake in switch specification. A switch with 24 PoE ports usually cannot deliver full power to all 24 at once — the total power budget is a separate figure from the port count. High-draw devices such as PTZ cameras, cameras with heaters and high-power access points consume the budget far faster than the port count suggests. When it runs out, devices fail to power up or reboot intermittently under load, which looks like a device fault. We calculate the budget against your actual devices plus headroom for what gets added later.
Beyond a handful of devices, managed. Managed switches give you VLANs to segment traffic, quality of service to prioritise voice and video, resilient link aggregation, port-level access control and — crucially — visibility of what is happening. Unmanaged switches are reasonable for very small static installations, but dropping one into a managed network creates a blind spot carrying traffic nobody can see or control.
Signal strength and performance are different things. The most common cause is interference between your own access points — Wi-Fi has a limited number of non-overlapping channels, and neighbouring units broadcasting loudly on the same channel spend their time waiting for each other. Adding more access points at full power makes this worse, not better. Other causes are uplink congestion behind the access points, and a design built for coverage where the actual problem is capacity. A survey identifies which it is.
For anything beyond a small office, yes. A survey is what separates a design from a guess. Predictive modelling from building plans gets you a starting point, but an on-site validation measures what the building actually does to the signal — and in Saudi buildings, reinforced concrete and block construction attenuates signal considerably more than the lightweight partitioning most predictive tools assume by default. A design based on generic wall types will consistently overestimate coverage.
Coverage means signal reaching everywhere — the problem in a warehouse or a yard with few simultaneous users. Capacity means handling many devices at once in a small space — the problem in a lecture theatre, a meeting room or a busy office floor. They call for opposite approaches: capacity needs more access points at lower power, coverage needs fewer with careful placement. Designing for the wrong one produces a network that looks fine on a signal map and performs badly in use.
We supply Cisco alongside other enterprise platforms, chosen against the requirement, the management model that suits your team, and locally available support. Platform choice is a long commitment — switches and access points stay in service for years and the management platform shapes how your team works — so it is worth discussing properly rather than picking on price.
No. Cameras, door controllers, printers and building management systems are network-connected computers running software that is often rarely updated, and on a flat network any one of them is a route to everything else. Cameras in particular are a recurring entry point in security assessments. Segmenting them onto their own network zones with access only to what they genuinely need limits how far a problem can spread, and it makes diagnosis considerably easier.
Copper Ethernet is limited to around a hundred metres including patch leads at both ends, which is less usable distance than people assume. Beyond that you need fiber, or an intermediate cabinet with a switch. On campuses, industrial sites and multi-building compounds this needs designing in from the start — discovering during installation that a run does not reach is expensive to correct.
It depends on how many sites you have and how much you rely on cloud services. SD-WAN manages multiple connections at each site as one, steering traffic by policy, sending cloud traffic straight to the internet rather than through a central site, and failing over automatically when a link degrades. For a distributed organisation with sites across the Kingdom it usually pays for itself in resilience and management effort. For a two-site organisation with a working connection, often not — and we will say so.
Yes, and it is a common starting point. We begin with an assessment covering the actual topology and how it grew, PoE headroom, uplink bottlenecks, wireless coverage and interference, segmentation, equipment age and support status, and how well any of it is documented. Inherited networks are frequently undocumented, which means the first deliverable is often a clear picture of what is actually there.
For a new site, tell us the building, the users and what has to run on the network, and we will design it. For an existing network that is not performing, an assessment will tell you what is actually wrong — which is frequently not what people assume. For Wi-Fi specifically, a survey is the only reliable way to know what you need.
Most facilities in the Kingdom deal with separate suppliers for power, IT and security, then discover the gaps between them at the worst possible moment. The UPS vendor points at the electrical contractor. The IT supplier says the rack was never their scope. Nobody owns the problem.
MHA Solutions covers all four disciplines with one engineering team. That means one point of accountability for the UPS, the distribution board feeding it, the server rack it protects and the access control system on the door of the room.
We work with industrial plants, healthcare facilities, government entities, data centres, telecom operators and major infrastructure contractors across Saudi Arabia. Our engineers handle the full lifecycle: site survey and load study, system design and specification, supply, installation, testing and commissioning, and ongoing maintenance under contract.
Equipment that performs well in a temperate climate does not always survive a Saudi plant room. Ambient temperatures above 45°C shorten battery life, airborne dust clogs filters and cooling paths, and salt-laden humidity on the Red Sea coast attacks enclosures and terminations. We specify for those conditions from the start, because replacing equipment early is far more expensive than sizing it correctly on day one.
Discover Our JourneyHappy customers
Brand partnerships
Years in business
Countries Served

Explore engineered solutions for mission-critical environments across power, IT and security.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.