MHA Solutions supplies and installs server racks, network cabinets, intelligent power distribution and containment for data centres, equipment rooms and industrial sites across Saudi Arabia. Specified for the heat load going into them, the floor they stand on and the power feeding them — because a rack is a thermal and electrical problem before it is a place to put equipment. Racks get treated as furniture. They are bought on height and price, delivered, filled with whatever needs housing, and then quietly become the reason equipment runs hot, the room trips a breaker, or nobody can trace a cable without unplugging three others. What a rack actually does is manage three things: airflow, power and weight. Equipment produces heat that has to leave the cabinet in a controlled direction. Equipment draws current that has to be distributed, balanced and monitored. And the whole assembly ends up heavy enough that the floor, the route to the room and the lift all matter. Most rack problems trace back to one of those three being ignored at purchase. A cabinet with solid doors bought because it looked tidier, and now the servers inside sit in their own exhaust. Half-empty racks with no blanking panels, so hot air loops straight back to the equipment intakes. A single power strip feeding servers that have two power supplies, which means the redundancy everyone paid for does not exist. Or a room where nobody knows how much power each rack is drawing, so capacity planning is guesswork until something trips. We specify racks against the heat load, the power requirement and the physical constraints of the room they are going into — and we install them, including the power distribution, containment, cabling and the electrical work behind it. That covers everything from a single wall-mounted cabinet in a branch office to rows of cabinets with containment in a data hall.
Equipment schedule and future capacity, heat load calculation against room cooling capacity, dimensional sizing including depth, power requirement and PDU selection, floor loading and access route survey, and containment where density requires it. The output is a specification you can order against with the assumptions stated.
Cabinets, containment, power distribution, cable management and accessories, delivered and installed. Installation covers positioning and levelling, anchoring, earthing and bonding, PDU mounting and connection, cable management and blanking — including the blanking, which is the item most likely to be omitted.
Mounting and cabling equipment into the cabinets, structured patching, labelling to a documented scheme, and dressing cables so that future changes do not require dismantling the bundle. Labelling and documentation are what make the installation maintainable by someone who was not there when it was built.
PDU sizing with appropriate headroom, phase balancing across the rack and the row, dual-feed arrangements from genuinely independent sources, and the circuits and distribution behind them — designed together as one scope rather than as separate contracts.
Assessment of existing rooms — intake temperatures at the cabinets, recirculation and bypass paths, blanking and sealing gaps, aisle arrangement — with a remediation plan. This is frequently the cheapest performance improvement available in an equipment room, and it is available on installations we did not build.
Environmental sensors, intelligent power distribution with per-outlet metering, cabinet-level electronic locking with audit trail, and integration with your building systems.
Rack and equipment relocation, consolidation of scattered cabinets into a properly designed room, and decommissioning — planned around the downtime window available.
Talk to MHA Solutions for expert advice on Power, IT, and Security systems that fit your space. We cover Riyadh, Jeddah, Dammam, and other cities with custom plans.
.png)
Full-height enclosed cabinets with highly perforated front and rear doors, adjustable mounting rails, cable management and space for vertical power distribution. The standard choice for equipment rooms and data halls, and the type where airflow specification matters most.
Highly perforated front and rear doors
.png)
Cabinets configured for patching and network equipment rather than servers — generally shallower, with more vertical and horizontal cable management, and often glass or solid front doors since patch panels and switches produce far less heat than a rack of servers. Depth still needs checking against the deepest switch going in.
More vertical and horizontal cable management
.png)
Compact enclosures for branch offices, floor communications rooms, retail sites and anywhere without space for a floor-standing cabinet. Available in hinged designs that swing away from the wall for rear access, which is worth specifying because working in a fixed wall cabinet is genuinely difficult. Wall fixings need to suit the wall construction and the loaded weight.
Hinged designs for rear access
.png)
Two-post and four-post open racks with no doors or side panels, used where physical security is not a requirement and unrestricted access and airflow are. Common for patching frames and in secured rooms where the room itself provides the security. Cheaper and considerably easier to work in.
Two-post and four-post
.png)
Cabinets divided into separately lockable compartments so multiple tenants or departments share one footprint with independent access, typically alongside per-outlet metered power so consumption can be attributed.
Separately lockable compartments
.png)
Sealed, ingress-protected enclosures for plant areas, workshops, outdoor locations and remote sites — with filtered ventilation or active cooling, and corrosion-resistant finishes where the environment demands it. On coastal sites the finish specification matters as much as the ingress rating.
Sealed, ingress-protected, corrosion-resistant finishes
.png)
Cold aisle or hot aisle containment with doors, roof panels and blanking, for installations where density justifies separating the two air streams completely.
Cold aisle or hot aisle containment
.png)
Blanking panels, brush strips and sealing grommets, vertical and horizontal cable managers, shelves, drawers, patch panels, earthing kits and monitoring sensors. The unglamorous items on this list are the ones that determine whether the installation works.
The items that determine whether the installation works
Cabinet rows with containment, per-outlet metered power for attribution and capacity planning, and airflow design that supports the intended density rather than limiting it.
Equipment cabinets at exchanges, base station sites and transmission rooms, including outdoor and unconditioned locations requiring sealed, actively cooled enclosures.
Filtered or sealed enclosures for plant floors and control rooms, housing automation, control and network equipment in environments where a standard cabinet would fill with dust.
Equipment rooms with cabinet-level access control and audit trail, consistent labelling, and documentation suitable for audit.
Distributed communications rooms across large hospital sites, with monitoring and consistent standards across every floor and building.
Shared and colocation cabinets with independent locking and metered power for attribution between tenants or departments.
Campus communications rooms and distribution frames, standardised across buildings so the estate stays supportable.
Rack sizing looks simple and has one dimension that catches people out repeatedly.
Measured in rack units, each one 44.45 millimetres of mounting space, and it is the dimension everyone considers. Full-height cabinets for equipment rooms and data halls generally sit in the low-to-mid forties, and the practical question is not how much equipment you have today but how much space the installation needs in three years — plus the space that patching, cable management and blanking will consume, which is more than people allow for.
Matters more than it appears. The standard cabinet width accommodates standard equipment mounting perfectly well. A wider cabinet does not hold more equipment; it provides vertical space beside the mounting rails for cable management and vertically mounted power strips. On a rack carrying a lot of patching or a high port count, that space is the difference between a cabinet you can work in and one where every change means fighting a cable bundle.
The dimension most often under-specified, and it is the one that causes real problems. The cabinet has to accommodate the deepest piece of equipment going into it, plus the cable bend radius and connectors behind it, plus the vertical power strips, plus enough clearance for air to actually move. A cabinet that is technically deep enough for the server is frequently not deep enough for the server plus everything that has to fit behind it — and unlike height, you cannot fix it later without replacing the cabinet.
A specification decision rather than a finish. Server cabinets need highly perforated front and rear doors so air can pass through; a solid or lightly perforated door on a cabinet full of servers is a thermal problem that will not be obvious until summer. Solid doors belong on cabinets holding passive equipment such as patching, not on anything that generates heat.
We size against the equipment list and the room rather than against a standard configuration, because retrofitting any of these is expensive.
Almost all IT equipment draws cool air in at the front and exhausts hot air at the back. Every rack decision either supports that or fights it.
The basic arrangement is to face rows of cabinets front-to-front and back-to-back, so cool air is delivered to one aisle and hot exhaust is collected in another. Racks arranged all facing the same direction feed the exhaust of one row directly into the intakes of the next, and the equipment at the far end of the room runs measurably hotter than the equipment at the near end for no reason anyone can see from the front.
Blanking panels are the cheapest and most neglected control in the room. Any unused mounting space in a rack is an open path between the hot side and the cold side. Hot exhaust air takes it, loops back to the front of the cabinet, and gets drawn straight back into the equipment intakes — so the servers are recirculating their own exhaust while the room cooling reports that the ambient is fine. Filling unused spaces with blanking panels costs very little and produces a genuinely measurable drop in intake temperature. Most racks we survey have none.
Cable entry points do the same thing on a smaller scale. Openings in the base, roof or side panels let air bypass the equipment entirely, so cooling capacity is spent moving air that never touches a server. Brush strips and sealing grommets close them without preventing access.
Containment is the next step where density justifies it. Enclosing either the cold aisle or the hot aisle with doors and roof panels stops the two air streams mixing at all, which allows higher rack densities and lets the cooling run more efficiently because it is handling a genuinely hot return rather than a diluted one.
Rack-level cooling is the answer where a room cannot support a particular density. Rear-door heat exchangers and in-row cooling place the cooling capacity beside the load instead of relying on the room to carry heat across a distance.
And monitoring is what tells you any of this is working. Temperature sensors at the front intakes — top, middle and bottom of the cabinet, since the top of a rack runs hottest — give you actual intake temperatures rather than a single room reading that averages away the problem.
None of this is exotic and none of it is expensive relative to the equipment it protects. It is simply skipped, and the consequence appears months later as thermal throttling, shortened hardware life, and unexplained restarts that get blamed on software.
A fully populated server cabinet is not a light object. Between the cabinet, the equipment, the batteries in any rack-mounted UPS and the cabling, the total is substantial enough to require checking rather than assuming — particularly where several cabinets sit together.
Two things need to be established before anything is ordered.
Rack loads are concentrated on levelling feet or castors, so the point loading is considerably higher than the average figure across the footprint suggests. Raised access floors have published limits for both distributed and point loading, and those limits assume the panels are supported as designed and in good condition. Upper-floor equipment rooms have their own structural limits. Where a row of cabinets is going in, this is worth confirming with the building information rather than discovering afterwards. Load-spreading plates are a straightforward solution where the point loading is the issue.
Cabinets are typically delivered assembled, and they are tall. The route from the loading bay to the room has to accommodate the height and width through every doorway, the lift car dimensions and its load rating, the corridor turns, and the floor loading along the whole path — not just at the destination. Ramps, thresholds and lift door heights are the usual points of failure. We survey the route as part of the installation planning, because a cabinet that cannot reach the room is an expensive problem to solve on delivery day.
Where access is genuinely constrained, flat-pack cabinets assembled in the room are the answer, and they are worth specifying early rather than as an emergency measure.
Finally, anchoring. Tall cabinets should be secured, both for stability when equipment is pulled out on rails and because the room may have seismic requirements depending on the building and its use.
Rack power distribution units range from a strip of outlets with no intelligence to units that meter every outlet individually and report environmental conditions. Which you need depends on what you are trying to manage.
Simply distribute power. They are appropriate for network cabinets and small installations where the load is known, static and modest.
Report the current being drawn, which is what makes capacity planning possible. Without metering, nobody knows how close a rack is to its limit, so either capacity is left unused because it feels safer or a breaker eventually trips and tells everyone the hard way. On any rack that will grow, metering pays for itself the first time it prevents that.
Allow individual outlets to be turned off and on remotely — useful for power-cycling an unresponsive device without sending someone to site, which matters at remote locations.
Combine per-outlet metering with switching and environmental sensor inputs, giving visibility of exactly what each device draws. On a shared or colocation environment where power is billed, per-outlet metering is the billing mechanism.
Three practical points that get missed more often than the product selection does.
A continuously running load should not be sized to the full nameplate rating of the circuit feeding it. Standard practice is to leave meaningful headroom, and a rack planned to the full rating of its PDU has no room for a single additional device or for the inrush when equipment restarts after an outage.
Where racks are fed from a three-phase supply, the load needs to be distributed across the phases rather than accumulating on one. Unbalanced loading wastes capacity and stresses the upstream distribution, and it happens gradually as equipment is added without anyone tracking which phase it landed on.
Servers with two power supplies only deliver redundancy if the two supplies are fed from genuinely independent sources — separate PDUs, on separate circuits, from separate distribution boards. Two cords into the same power strip is one of the most common installation errors in this field, and it converts a redundancy feature into a decoration. We check this at commissioning, including on installations we did not build.
We size, supply and install rack power distribution as part of the electrical works, so the PDU, the circuit feeding it and the distribution board behind it are designed together.
Three things that belong in the rack specification and are usually added later, at greater cost.
Temperature sensors at the front intakes — top, middle and bottom of the cabinet, since the top runs hottest — give you the temperature the equipment actually experiences rather than a single room reading that averages the problem away. Humidity, door position and water leak detection are worth adding where the installation warrants it. Modern intelligent power distribution units accept sensor inputs directly, so the monitoring can be built around equipment already in the rack rather than as a separate system.
Lockable front and rear doors and side panels are standard; the decision is whether keyed locks are sufficient or whether electronic locking with a logged audit trail is required. In shared rooms, multi-tenant facilities and environments handling regulated data, cabinet-level access control with a record of who opened which cabinet and when is frequently a compliance requirement rather than a preference. It can integrate with the building access control system rather than standing alone.
Racks and the equipment in them must be bonded to the earthing system properly — cabinet frame, doors and side panels, mounting rails and equipment, using proper bonding kits rather than relying on the incidental contact between painted panels. It is a safety requirement and it is routinely done inconsistently. Because we carry out the electrical works, the rack bonding and the room earthing are part of the same scope.
Everything in the airflow section above matters more here than it does in a temperate climate, because the room has less margin to absorb a thermal problem.
The constraint behind every rack decision. An equipment room that copes in February can be at its limit in August, and adding a populated cabinet to a room already running near capacity is a decision that should be made with the cooling figures in front of you rather than by seeing that there is floor space. We check the room before quoting the cabinet.
Affects racks in plant areas, workshops and site offices, accumulating on door perforations and equipment intakes and progressively reducing the airflow the design assumed. Filtered enclosures with a realistic filter replacement schedule are the answer where a cabinet has to live in that environment — and the schedule needs to reflect the actual dust load rather than a manufacturer default.
Affect the finish rather than the function. Salt-laden humid air attacks cabinet paint, fixings and door hardware, so on the Red Sea coast the finish specification and hardware material are worth deciding deliberately.
Need sealed enclosures with active cooling rather than filtered ventilation, because ventilation only helps when the outside air is cooler than the inside — which, for a large part of the year, it is not.
We supply and install rack infrastructure Kingdom-wide from our base in Jeddah — Riyadh, Dammam, Khobar, Jubail, Yanbu, Makkah, Madinah, Taif and remote industrial and telecom sites. Surveys, installation and airflow assessments are carried out by our own engineers.
Height should reflect what the installation will hold in a few years rather than today, and should allow for the patching, cable management and blanking that consume more space than people expect. Depth is the dimension most often under-specified and the one you cannot fix later — the cabinet has to take the deepest equipment plus cable bend radius, connectors, vertical power strips and airflow clearance behind it. A wider cabinet does not hold more equipment; it gives you vertical space for cable management, which matters on racks carrying a lot of patching.
Every unused mounting space in a rack is an open path between the hot rear of the cabinet and the cool front. Hot exhaust air takes it, loops back to the front, and gets drawn straight into the equipment intakes — so your servers recirculate their own exhaust while the room cooling reports that everything is fine. Blanking panels cost very little and produce a genuinely measurable reduction in intake temperature. Most racks we survey have none fitted.
Anything containing servers or other heat-generating equipment needs highly perforated front and rear doors so air can pass through. A solid door on a server cabinet traps exhaust air and creates a thermal problem that will not be obvious until the first hot month. Solid or glass doors are fine on cabinets holding passive equipment such as patch panels and small switches, where the heat output is minimal.
It means arranging cabinet rows front-to-front and back-to-back so cool air is delivered to one aisle and hot exhaust collected in another, rather than every row feeding its exhaust into the next row's intakes. It costs nothing to do at design stage and makes a real difference to equipment intake temperatures. Full containment — enclosing one of the aisles with doors and roof panels — is the next step and is worth it where rack density is high or the room is struggling.
Basic units are fine for network cabinets with a known static load. Metered units report current draw, which is what makes capacity planning possible — without it, nobody knows how close a rack is to its limit until a breaker trips. Switched units allow remote power-cycling of individual outlets, which is valuable at remote sites. Intelligent units add per-outlet metering, which is the billing mechanism in shared or colocation environments. For most growing installations, metered is the minimum worth buying.
Only if the two supplies are fed from genuinely independent sources — separate PDUs, on separate circuits, from separate distribution boards. Plugging both cords into the same power strip is one of the most common installation errors in this field, and it turns redundancy into decoration: the single point of failure everyone paid to remove is still there. We check this at commissioning, including on installations we did not build.
It needs checking rather than assuming, particularly for a row of cabinets or an upper-floor equipment room. Rack loads concentrate on levelling feet or castors, so point loading is considerably higher than the average across the footprint. Raised access floors have published distributed and point load limits which assume the panels are supported as designed and in good condition. Where point loading is the constraint, load-spreading plates are a straightforward solution.
This needs surveying before ordering. Cabinets are usually delivered assembled and are tall, so the route from the loading bay matters as much as the destination — doorway heights and widths, lift car dimensions and load rating, corridor turns, ramps and thresholds, and floor loading along the whole path. Where access is genuinely constrained, flat-pack cabinets assembled in the room solve it, but that should be specified at order stage rather than decided on delivery day.
Yes, with the right enclosure. Plant areas and workshops need sealed or filtered cabinets to keep dust off equipment intakes, with a filter replacement schedule that reflects the actual dust load rather than a manufacturer default. Genuinely outdoor or unconditioned locations need sealed enclosures with active cooling rather than filtered ventilation, because ventilation only helps when the outside air is cooler than the inside — which here, for much of the year, it is not.
Usually, yes, and it is often the cheapest performance improvement available. An airflow assessment measures actual intake temperatures at the cabinets and identifies recirculation and bypass paths — missing blanking, unsealed cable entries, cabinet orientation, obstructed airflow. Fitting blanking panels, sealing entry points and correcting aisle arrangement frequently produces a meaningful reduction in intake temperature for a very small spend, without buying a single new cabinet.
Tell us what equipment is going in, where the room is and what cooling it has, and we will specify the cabinets, power distribution and containment to suit — including an honest view on whether the room can support what you are planning to put in it. If you have an existing room that runs hot, an airflow assessment is usually the cheapest place to start.
Most facilities in the Kingdom deal with separate suppliers for power, IT and security, then discover the gaps between them at the worst possible moment. The UPS vendor points at the electrical contractor. The IT supplier says the rack was never their scope. Nobody owns the problem.
MHA Solutions covers all four disciplines with one engineering team. That means one point of accountability for the UPS, the distribution board feeding it, the server rack it protects and the access control system on the door of the room.
We work with industrial plants, healthcare facilities, government entities, data centres, telecom operators and major infrastructure contractors across Saudi Arabia. Our engineers handle the full lifecycle: site survey and load study, system design and specification, supply, installation, testing and commissioning, and ongoing maintenance under contract.
Equipment that performs well in a temperate climate does not always survive a Saudi plant room. Ambient temperatures above 45°C shorten battery life, airborne dust clogs filters and cooling paths, and salt-laden humidity on the Red Sea coast attacks enclosures and terminations. We specify for those conditions from the start, because replacing equipment early is far more expensive than sizing it correctly on day one.
Discover Our JourneyHappy customers
Brand partnerships
Years in business
Countries Served

Explore engineered solutions for mission-critical environments across power, IT and security.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.