.png)
End-to-End Infrastructure Excellence
MHA Solutions designs, installs, tests and certifies copper and fiber optic cabling for offices, campuses, hospitals, industrial sites and data centres across Saudi Arabia. Every link is tested to standard and the results issued as part of the handover — because a cabling installation that has not been certified is one you have to take on trust, and you will only find out during a fault. Cabling is installed once and then lives in the walls and ceilings for fifteen or twenty years, carrying every generation of equipment that gets connected to it in that time. It is also the cheapest part of the network to install and by far the most expensive to replace, because replacing it means going back into the fabric of an occupied building. Which makes it strange how often it is bought on price per point. The consequences of a poor installation are rarely obvious at handover. Everything passes a basic connectivity check, the network works, and the job is signed off. The problems appear later: links that will not support the next equipment upgrade because the cable specified was adequate for the speed at the time and nothing more. Intermittent faults on particular ports that nobody can trace because the installation was never tested and there is no baseline to compare against. Ports that cannot be identified because the labelling scheme was invented on site and never documented. And a fault that takes a day to locate because nobody knows which cable goes where. We install to the recognised standards, test and certify every link with the results issued as a report, and label and document the installation so that whoever works on it in five years can understand it without guessing. Where the manufacturer offers an extended system warranty, we install to the requirements that make it valid — which is covered below, and is worth more than most people realise. We work on new build, fit-out, extension and remediation, from a floor of offices to campus and industrial sites with fiber backbones between buildings.
Site survey, outlet schedule, telecommunications room placement and sizing, containment and pathway design, category and fiber grade selection against present and future requirements, and a labelling scheme. Delivered as a documented design you can build or tender against.
Cat6 and Cat6A horizontal and backbone cabling, outlets, patch panels and patching, with containment and cable management installed by our own team. Runs are set out to respect distance limits and bend radius rather than corrected afterwards.
Multimode and singlemode backbone, riser and inter-building fiber, fusion spliced and terminated, with enclosures, patching and protection appropriate to the route. Including external and underground routes where the design requires them.
Certification of every copper link against its category standard and every fiber link against its loss budget, with OTDR tracing where warranted. Results issued as a report per link, and submitted for manufacturer warranty registration where applicable.
A consistent labelling scheme applied at both ends and on patch panels, as-built drawings, port schedules and the complete test record. This is the deliverable that makes the installation maintainable and it is the one most often skimped.
Structured patching within and between cabinets, high-density fiber, pre-terminated trunk systems, containment and cable management designed so that airflow is not obstructed by the cabling.
Additions to existing installations matched to the current scheme, remediation of installations that fail certification or cannot support an equipment upgrade, and fault location on cabling we did not install — which, on an undocumented installation, usually starts with establishing what is actually there.
Cabling for CCTV, access control, wireless access points and building systems, designed as part of the same structured system rather than as separate ad-hoc runs. Treating them as one system is what keeps a building maintainable.
Talk to MHA Solutions for expert advice on Power, IT, and Security systems that fit your space. We cover Riyadh, Jeddah, Dammam, and other cities with custom plans.
Copper category is the decision that determines how long the installation stays useful, and it is worth thinking about in terms of the equipment you will connect in ten years rather than the equipment you are connecting now.
.png)
Legacy. It supports gigabit and nothing beyond it reliably. It should not be specified for a new installation, though it is still perfectly serviceable where it is already installed and gigabit is sufficient.
Gigabit · legacy
.png)
Supports gigabit comfortably and 10 gigabit only over reduced distances — not across a full horizontal run. It remains widely specified because it is cheaper, and it is a reasonable choice where the requirement is genuinely gigabit and will stay that way.
Gigabit · 10 gigabit over reduced distances
.png)
Supports 10 gigabit across the full horizontal distance, and it is the sensible default for most new installations. The cable is physically larger with a greater bend radius, which affects containment sizing and pathway capacity, and it costs more to buy and to install. What it buys is headroom — an installation that will still carry whatever gets plugged into it a decade from now.
10 gigabit across the full horizontal distance
Office fit-out and refurbishment, floor distribution, meeting room and desk provision, and cabling for wireless access points and building systems as one structured installation.
Hospital and clinic cabling across large multi-building sites, with segregated systems where clinical requirements demand it, high resilience on backbone routes, and phased installation around occupied departments.
Campus backbone between buildings, classroom and laboratory provision, and dense wireless access point cabling — with distance planning across the site established early.
Plant and process area cabling with jacket and containment specification suited to the environment, shielded systems where interference demands them, and fiber for distance and electrical isolation.
High-density structured patching, pre-terminated trunk systems, and cable management designed so it does not obstruct airflow — which is a thermal decision as much as a tidiness one.
Guest room and back-of-house provision at high point counts, with phased installation around occupancy.
Documented, certified installations with full handover records suitable for audit and long-term facilities management.
There is a second reason Cat6A is increasingly the right answer, and it is one that gets overlooked: power. As Power over Ethernet standards have increased the power delivered per port, the heat generated in a bundle of cables carrying that power has become a genuine design consideration. Larger conductors dissipate heat better and are affected less, and in a hot ceiling void carrying a large bundle of PoE-powered devices, that matters more here than in most markets.
Shielded or unshielded is the other decision. Unshielded cabling is standard for most commercial environments and is simpler to install. Shielded cabling is worth specifying where there is significant electrical interference — industrial environments, close routing alongside power cabling, plant areas — but it only works if the shield is correctly bonded throughout, and a shielded system installed without proper bonding performs worse than an unshielded one. That is an installation quality question rather than a product question.
Fiber is required wherever distance exceeds what copper can carry, wherever electrical isolation matters, and wherever the bandwidth requirement is beyond what copper supports economically. In practice that means building backbones, links between buildings, campus and industrial site distribution, and data centre connectivity.
The hundred-metre copper limit is the usual trigger. It includes the patch leads at both ends, so the usable installed run is shorter than people assume — and on a campus, an industrial site or a multi-building compound, that limit is reached quickly. Any run between buildings should be assumed to need fiber until proven otherwise.
Multimode fiber is used for shorter runs — within buildings and across most campuses. The OM grades differ in the distance they support at a given speed, with the higher grades carrying faster speeds further. The practical decision is the same as with copper category: specifying a higher grade costs a little more now and preserves the ability to upgrade the electronics later without pulling new fiber.
Singlemode fiber supports far greater distances and effectively unlimited bandwidth for the ranges seen in commercial installations. The transceivers cost more, but on long campus runs, links between distant buildings and anything that may need upgrading later, it is frequently the better long-term decision. For a link between buildings that will be difficult to re-cable, singlemode is usually the right answer even where multimode would work today.
Termination is done by fusion splicing to pre-terminated pigtails for permanent installations, which gives low loss and reliable performance. Where installations use pre-terminated trunk assemblies — common in data centres — the design has to be right first time, because the lengths are fixed at manufacture.
Every fiber link is tested for loss and, where the installation warrants it, traced with an OTDR to characterise the link and record a baseline. The testing section below covers why the baseline matters.
Cabling manufacturers offer extended system warranties — typically covering the installed system for a period measured in decades rather than years, guaranteeing both the components and the performance of the installed links.
These warranties are not automatic. They require three things: components from a single manufacturer's system throughout rather than a mixture assembled on price, installation by an accredited installer trained and approved by that manufacturer, and certified test results for every link submitted as evidence.
That third requirement is the one that matters most practically, because it means the installation has to be tested properly and documented. An installer who cannot produce certified results for every link cannot register the warranty, whatever else they say.
Why it is worth having: it covers performance rather than just parts. If a link fails to support the speed it was certified for, the warranty engages — which on an installation with several hundred points is a meaningful protection over twenty years. It also removes the argument about whether a fault is the cable or the equipment, because a certified link with a registered warranty has a documented performance baseline.
And it is a proxy for installation quality. Manufacturers do not extend twenty-year performance warranties to installations they have not seen evidence for, so the requirements themselves — single-system components, accredited installation, full certification — are a description of what a good installation looks like.
When comparing quotations, this is worth asking about directly. A quotation that is meaningfully cheaper per point is frequently cheaper because it uses mixed components, skips full certification, or both — and the difference only becomes visible years later, when there is no warranty to call on and no test results to reference.
A continuity check confirms that a cable is connected. Certification confirms that it will actually perform to the category it was installed as, which is a different question entirely — and the one that determines whether the installation supports your next equipment upgrade.
Copper certification uses a calibrated tester to measure each link against the performance requirements of its category: wiremap and continuity, insertion loss, near-end and far-end crosstalk, return loss, propagation delay and delay skew. Each link passes or fails against the standard, and the results are stored per link with the label reference.
These are not abstract measurements. A link that passes a continuity test and fails on crosstalk will work at gigabit and fail intermittently at ten gigabit — which is exactly the fault that appears years later after an equipment upgrade and takes days to diagnose, because nobody has a baseline.
Fiber testing measures optical loss across the link against a calculated budget, and where the installation warrants it, OTDR tracing characterises the link and records the position and loss of every splice and connector. That trace is a baseline: when a fault occurs later, comparing against it identifies where the problem is rather than requiring the whole route to be investigated.
Connector cleanliness deserves specific mention because it is the single most common cause of fiber problems, and it is worse in dusty environments. A fiber connector end face is small enough that a single particle of dust can cause significant loss, and connecting a contaminated connector can transfer contamination and damage the mating face. Inspection and cleaning as standard practice before every connection is the answer, and it is routinely skipped.
All results are issued as a test report forming part of the handover documentation, alongside as-built drawings and the labelling schedule. That package is what makes the installation maintainable — and, where applicable, what registers the manufacturer warranty.
Structured cabling standards exist so that an installation is predictable, testable and maintainable by someone who did not build it. The relevant family in Saudi Arabia follows American practice, consistent with the wider electrical code — covering the cabling system itself, the pathways and spaces that carry it, the administration and labelling scheme, and the bonding and earthing arrangements.
The design decisions that matter most in practice:
Every horizontal run has to reach from there to its outlet within the distance limit including patching at both ends. Rooms placed for convenience rather than geometry produce runs that are technically over-length and fail certification, discovered at testing when the containment is already installed.
Sized for what will be added later, not just what is being installed now. Containment that is full on day one means the next project runs cable outside it.
With adequate spacing or segregated containment, because running data alongside power induces interference. This is a design decision, not something to resolve on site.
Respected throughout — over-tight bends degrade performance on copper and cause loss and eventual failure on fiber, and cable pulled around a sharp corner is damaged permanently even though it tests acceptably at handover.
To a documented scheme applied consistently at both ends and on the patch panels. This is the difference between locating a fault in minutes and tracing cables by hand.
The handover package covers as-built drawings, the labelling schedule, certified test results per link, component details and warranty registration where applicable. It is what the next person inherits, and it is what separates an installation that can be maintained from one that has to be re-surveyed every time something changes.
Ceiling voids, risers and unshaded external ducts run considerably hotter than the conditioned space below them. Cable performance is specified at a reference temperature, and elevated temperature increases insertion loss — which reduces the margin a link has against its certification limits. On long runs in hot routes this is the difference between a link that passes and one that does not, and it is a design input rather than an installation surprise.
As PoE standards deliver more power per port, the current carried in a cable bundle generates measurable heat, and that heat is trapped in the middle of a large bundle. In a ceiling void already at elevated temperature, bundle size and cable specification both become design considerations. Larger conductors handle it better, which is a further argument for Cat6A on installations feeding a lot of powered devices — cameras, access points, door controllers and phones.
Campuses, industrial sites and multi-building compounds routinely exceed what copper can carry. Fiber backbone should be assumed for anything between buildings and designed in from the start rather than discovered when a run fails to reach.
Contamination is the leading cause of fiber faults anywhere, and it is worse in dusty environments. Inspection and cleaning before every connection, and protective caps kept on unmated connectors, are standard practice for us rather than an optional step.
Where cabling runs through plant areas, the containment, cable jacket specification and routing all need to reflect the environment — mechanical damage, chemicals, temperature and interference from nearby machinery.
We design, install, test and certify cabling systems Kingdom-wide from our base in Jeddah — Riyadh, Dammam, Khobar, Jubail, Yanbu, Makkah, Madinah, Taif and remote industrial sites. Installation, termination, testing and certification are carried out by our own teams.
Cat6A for most new installations. Cat6 supports gigabit comfortably and 10 gigabit only over reduced distances, not a full horizontal run — so an installation cabled in Cat6 may not support an equipment upgrade later without recabling. Cat6A supports 10 gigabit across the full distance. It costs more and needs larger containment because the cable is physically bigger. Given that cabling stays in the building for fifteen or twenty years and is far more expensive to replace than to install, the headroom is usually worth it.
Usually only where there is genuine electrical interference — industrial environments, routes running close alongside power cabling, or plant areas. For standard commercial installations, unshielded is the norm and is simpler to install correctly. Important caveat: shielded cabling only performs if the shield is properly bonded throughout the system. A shielded installation with inconsistent bonding performs worse than an unshielded one, so it is a decision about installation quality as much as product choice.
Whenever the distance exceeds what copper carries — around a hundred metres including patch leads at both ends, which is less usable run than people expect. That means anything between buildings, most campus distribution and long industrial site runs. Fiber is also used for high-bandwidth backbone and where electrical isolation between buildings matters. For a link between buildings that would be difficult to re-cable, it is worth specifying singlemode even if multimode would do today.
Cabling manufacturers offer extended warranties covering the installed system for decades rather than years, guaranteeing components and performance. Three things are required: components from one manufacturer's system throughout, installation by an installer accredited by that manufacturer, and certified test results for every link submitted as evidence. It covers performance rather than just parts, and it removes the argument about whether a fault is the cable or the equipment — because the link has a documented baseline.
A continuity test confirms a cable is connected correctly. Certification measures the link against the full performance requirements of its category — insertion loss, crosstalk, return loss, delay — and confirms it will actually carry the speed it was installed for. A link can pass continuity, work fine at gigabit, and fail intermittently at ten gigabit. That fault surfaces years later after an equipment upgrade and takes days to diagnose if there is no certification baseline to compare against.
Because it is the difference between locating a fault in minutes and tracing cables by hand through a ceiling. A consistent labelling scheme applied at both ends and on the patch panels, with as-built drawings, port schedules and test records, is what makes an installation maintainable by someone who was not there when it was built. It is also the part most often reduced to save cost, and the omission is invisible until the first time somebody needs it.
Yes. Ceiling voids, risers and external ducts run well above the conditioned space, and elevated temperature increases insertion loss — reducing the margin a link has against its certification limits. On long runs in hot routes this can be the difference between passing and failing certification. Power over Ethernet compounds it: higher-power PoE generates heat in cable bundles, trapped in the middle of large bundles. Both are design inputs, and both favour Cat6A on installations feeding many powered devices.
Contamination on connector end faces is the leading cause, and it is worse in dusty environments. A fiber connector end face is small enough that a single dust particle causes significant loss, and mating a contaminated connector can transfer contamination and damage the other face. Inspection and cleaning before every connection prevents most fiber faults, and it is routinely skipped. An OTDR baseline recorded at installation also makes later fault location far quicker.
Yes. Extensions are matched to the existing scheme where one exists, and where it does not, establishing what is actually installed is usually the first task. We also remediate installations that fail certification or cannot support a planned equipment upgrade, and carry out fault location on undocumented systems. If the existing installation is undocumented, a survey and certification of what is there is often the most useful thing we can do first.
The cabling itself lasts decades. What determines the useful life is whether it supports the equipment you connect to it over that period — which is why category and fiber grade selection matter more than almost any other decision. A well-installed, well-documented, correctly specified system will outlast several generations of network equipment. An under-specified one becomes the constraint on your next upgrade, and replacing it means going back into an occupied building.
Send us the drawings, the outlet requirement or a description of the site, and we will produce a design, a specification and a quotation — including the category and fiber grade we recommend and why. If you have an existing installation that is undocumented or failing, a survey and certification of what is there is usually the right first step.
Most facilities in the Kingdom deal with separate suppliers for power, IT and security, then discover the gaps between them at the worst possible moment. The UPS vendor points at the electrical contractor. The IT supplier says the rack was never their scope. Nobody owns the problem.
MHA Solutions covers all four disciplines with one engineering team. That means one point of accountability for the UPS, the distribution board feeding it, the server rack it protects and the access control system on the door of the room.
We work with industrial plants, healthcare facilities, government entities, data centres, telecom operators and major infrastructure contractors across Saudi Arabia. Our engineers handle the full lifecycle: site survey and load study, system design and specification, supply, installation, testing and commissioning, and ongoing maintenance under contract.
Equipment that performs well in a temperate climate does not always survive a Saudi plant room. Ambient temperatures above 45°C shorten battery life, airborne dust clogs filters and cooling paths, and salt-laden humidity on the Red Sea coast attacks enclosures and terminations. We specify for those conditions from the start, because replacing equipment early is far more expensive than sizing it correctly on day one.
Discover Our JourneyHappy customers
Brand partnerships
Years in business
Countries Served

Explore engineered solutions for mission-critical environments across power, IT and security.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.
Engineering reliable infrastructure for critical facilities.